Fluke 707Ex Intrinsically Safe Loop Calibrator

Call for Price
*Price may change due to echange rate.
SKU
650231
SAP Item ID
651136
The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive in Zones 1 and 2.

This product is EOL (End Of Life)


Fluke 707Ex Intrinsically Safe Loop Calibrator

 

The fast one-handed tool for mA loop checks in Ex zones

The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.


Features:

  • Large display and simple, quick-click push rotary button for easy one-handed operation
  • Simultaneous mA and % readout for quick, easy, interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators
  • 1 µA resolution for mA source, simulate and measure
  • Push button with 25% steps for fast, easy linearity checks
  • 0-100% "span check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
  • Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
  • Measures Vdc to 28 V
  • Single 9 V battery that is easily changed
  • 0-20 mA or 4-20 mA default start up modes
  • Innovative output adjustment dial with 1 µA and 100 µA resolution
  • HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators

 

Specifications
Current measurement Range 0 to 24 mA
Resolution 0.001 mA
Accuracy 0.015% Rdg + 2 LSD
Current sourcing Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.015% Rdg + 2 LSD
Drive capability 700 Ω at 20 mA
Current simulation Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.015% Rdg + 2 LSD
Loop power While measuring mA, 24 V
Voltage measurement Range 0 to 28 V DC
Resolution 1 mV
Accuracy 0.015% Rdg + 2 LSD
Environmental Specifications
Operating temperature -10ºC to 55ºC
Storage temperature -40ºC to 60ºC
Humidity (without condensation) 0 to 95% (0ºC to 30ºC);

0 to 75% (30ºC to 40ºC)

0 to 45% (40ºC to 50ºC)

Temperature coefficient -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC
Safety Specifications
Safety CSA C22.2 No. 1010.1:1992
EMC EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage 30 V
ATEX certification Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X
CE certification EN61010-1 and EN61326
Mechanical and General Specifications
Size 152 x 70 x 41 mm
Weight 224 g (350 g including holster)
Batteries One 9V battery Alkaline
Warranty 3 year
Shock & vibration per MIL-T-28800 for a Class 2 Instrument
Display current and % of span Yes
Auto step, auto ramp Yes
Span check Yes

 

Downloads

 2072174_6110_ENGComm-Co.pdf

 

 
For orders under € 450 we charge € 25 order costs.
Prices shown on this website are before taxes, currency changes and shipping costs.
For an accurate price please contact our sales team at info@comm-co.com

More Information
Discontinued Yes
Write Your Own Review
You're reviewing:Fluke 707Ex Intrinsically Safe Loop Calibrator