Outdoor Units for ATEX Zones | Zone 2 & 22 Explosion-Proof Condensers

Get Your Quote From The Manufacturer
*Prices are Excl. VAT, duty and shipping costs and may change due to exchange rate.
SKU
42326214325634

ATEX-certified outdoor units provide the heat rejection component for split air conditioning systems in hazardous areas. Available in four series ranging from 2.0 to 25.0 kW, these rugged outdoor condensers are designed for Zone 2 and Zone 22 environments with operating temperatures from -20°C to +52°C.

Outdoor Units for ATEX Zones

Explosion-Proof Outdoor Condensers for Complete System Solutions

Outdoor units are the essential heat rejection component of split air conditioning systems, housing the compressor, condenser coil, and fan. Our ATEX-certified outdoor units are engineered to operate safely in Zone 2 and Zone 22 classified outdoor environments, or can be installed in safe areas when paired with ATEX indoor units. Built with anti-corrosion treatments and designed for extreme conditions, these units ensure reliable operation in the harshest industrial environments.

ATEX Certified: Zone 2 (3G) and Zone 22 (3D) | 5-Year Warranty Included | Worldwide Shipping


Choose Your Series

We offer four distinct series of outdoor units, each matched to their corresponding indoor unit series:

Feature Best Buy Series Classic Series Power Inverter Series High Ambient Series
OEM Partner Samsung Daikin Mitsubishi Electric Daikin Sky Air Alpha
Capacity Range 2.6 - 25.0 kW 2.0 - 7.1 kW 3.6 - 13.4 kW 3.5 - 13.4 kW
Models Available 9 models 7 models 7 models 7 models
Max Operating Temp +50°C +46°C / +50°C +46°C +52°C
Min Operating Temp -15°C -10°C / -21°C -15°C / -20°C -20°C
Compressor Type BLDC (Single/Twin/Scroll) Standard/Inverter Inverter BLDC Inverter
Best For Wide capacity range, budget-friendly Premium quality & reliability 24/7 continuous operation Extreme heat environments
Unique Feature Up to 25 kW available Wide operating range Enhanced reliability for 24/7 duty Operates to +52°C ambient

Best Buy Series Outdoor Units

Widest Capacity Range from 2.6 to 25 kW

Samsung-based outdoor units offering the most comprehensive capacity range. From small residential-sized units to high-capacity industrial models, the Best Buy series provides cost-effective outdoor solutions for any application.

Small Capacity Models (2.6 - 7.1 kW):

  • Ex-M BB26O - 2.6 kW cooling / 3.3 kW heating
  • Ex-M BB35O - 3.5/3.8 kW cooling / 4.0 kW heating
  • Ex-M BB52O - 5.0 kW cooling / 6.0 kW heating
  • Ex-M BB71O - 7.1 kW cooling / 8.0 kW heating

Large Capacity Models (10.0 - 25.0 kW):

  • Ex-M BB100O - 10.0 kW cooling / 11.2 kW heating
  • Ex-M BB120O - 12.0 kW cooling / 14.0 kW heating
  • Ex-M BB140O - 13.4 kW cooling / 15.5 kW heating
  • Ex-M BB200O - 20.0 kW cooling / 23.0 kW heating
  • Ex-M BB250O - 25.0 kW cooling / 27.0 kW heating

Key Specifications:

  • Refrigerant: R32 (R410A for 20-25 kW models)
  • Power Supply: 1-phase 220-240V (small models) / 3-phase 380-415V (large models)
  • Compressor: BLDC Single/Twin for small models, Scroll BLDC for large models
  • Operating Range: -15°C to +50°C cooling / -20°C to +24°C heating
  • Sound Level: 46-59 dB(A) cooling
  • Fan Type: Propeller (small models) / Sirocco (large models)
  • Dimensions: 790-1,630 x 285-460 x 548-998 mm (HxWxD)
  • Weight: 32.5 - 154.0 kg

Perfect for: Any application from small control rooms to large industrial facilities requiring high-capacity outdoor units at competitive prices


Classic Series Outdoor Units

Premium Daikin Reliability with Wide Operating Range

Daikin outdoor units engineered for reliability and efficiency. These units feature wide operating temperature ranges and proven compressor technology for consistent performance in demanding environments.

Available Models:

  • Ex-M CS20O - 2.0 kW cooling / 2.5 kW heating
  • Ex-M CS25O - 2.5 kW cooling / 2.8 kW heating
  • Ex-M CS35O - 3.4/3.5 kW cooling / 4.0/4.2 kW heating
  • Ex-M CS42O - 4.2 kW cooling / 5.4 kW heating
  • Ex-M CS50O - 5.0 kW cooling / 5.5/5.8/6.0 kW heating
  • Ex-M CS60O - 5.7/6.0 kW cooling / 7.0/7.2 kW heating
  • Ex-M CS71O - 7.1 kW cooling / 8.2 kW heating

Key Specifications:

  • Refrigerant: R32 (R410a retrofit available)
  • Power Supply: 1-phase, 220-240V, 50Hz
  • Operating Range: -10°C to +50°C cooling / -21°C to +18°C heating
  • Sound Level: 46-49 dB(A) cooling
  • Fan Type: Propeller
  • Heat Exchanger: Copper tubes with waffle fins, anti-corrosion treatment
  • Dimensions: 610/734 x 367/401 x 923/954 mm (HxWxD)
  • Weight: 36 - 55 kg

Perfect for: Premium installations prioritizing Daikin's renowned reliability and wide operating temperature range


Power Inverter Series Outdoor Units

Enhanced Durability for Continuous 24/7 Operation

Mitsubishi Electric outdoor units specifically engineered for round-the-clock operation. These inverter-driven units provide reliable heat rejection for systems that cannot afford downtime.

Available Models:

  • Ex-M PI35O - 3.6 kW cooling / 4.1 kW heating
  • Ex-M PI50O - 5.0 kW cooling / 5.5 kW heating
  • Ex-M PI60O - 6.1 kW cooling / 7.0 kW heating
  • Ex-M PI71O - 7.1 kW cooling / 8.0 kW heating
  • Ex-M PI100O - 9.5 kW cooling / 11.2 kW heating
  • Ex-M PI125O - 12.5 kW cooling / 14.0 kW heating
  • Ex-M PI140O - 13.4 kW cooling / 16.0 kW heating

Key Specifications:

  • Designed for: Continuous 24/7 operation
  • Refrigerant: R32 (R410a retrofit available)
  • Power Supply: 220-240V, 1-phase / 400V 3-phase for larger models
  • Operating Range: -15°C to +46°C cooling / -20°C to +21°C heating
  • Compressor: Inverter BLDC
  • Dimensions: 809/950/1,100 x 300/330/460 x 630/943/870 mm (WxDxH)
  • Weight: 46 - 121 kg

Perfect for: Mission-critical applications requiring uninterrupted operation, including storage facilities, battery rooms, and pharmaceutical production


High Ambient Series Outdoor Units

Maximum Heat Rejection up to +52°C Ambient

Specially engineered outdoor units for extreme heat environments. Based on Daikin's Sky Air Alpha platform with enhanced condensers and fan systems to maintain performance when ambient temperatures soar.

Available Models:

  • Ex-M HA35O - 3.5 kW cooling / 4.0 kW heating
  • Ex-M HA50O - 5.0 kW cooling / 5.8/6.0 kW heating
  • Ex-M HA60O - 6.0 kW cooling / 7.0 kW heating
  • Ex-M HA71O - 6.8 kW cooling / 7.5 kW heating
  • Ex-M HA100O - 9.5 kW cooling / 10.8 kW heating
  • Ex-M HA125O - 12.1 kW cooling / 13.5 kW heating
  • Ex-M HA140O - 13.4 kW cooling / 15.5 kW heating

Key Specifications:

  • Operating Range: -20°C to +52°C cooling / -20°C to +24°C heating
  • Refrigerant: R32 (R410a retrofit available)
  • Power Supply: 1-phase 220-240V / 3-phase 380-415V (larger models)
  • Sound Level: 47-50 dB(A) cooling
  • Fan Type: Propeller
  • Heat Exchanger: Enhanced waffle fin design with anti-corrosion treatment
  • Dimensions: 734/870 x 373/460 x 870/1,100 mm (HxWxD)
  • Weight: 52 - 95 kg

Perfect for: Middle East, Far East, and African installations where extreme ambient temperatures challenge standard outdoor units


Configuration Options

Outdoor units can be configured for three different installation scenarios:

Configuration 1: ATEX Indoor Unit + Standard Outdoor Unit in Safe Area

Most common and cost-effective setup. The ATEX-certified indoor unit operates in the hazardous zone while the standard outdoor unit is installed in a non-classified safe area.

Configuration 2: Standard Indoor Unit + ATEX Outdoor Unit for Zone 2

Used when the outdoor environment is classified as hazardous (Zone 2 or 22), such as outdoor processing areas on offshore platforms or chemical facilities.

Configuration 3: Both Units ATEX-Certified for Zone 2

Complete explosion-proof system when both indoor and outdoor locations are within classified hazardous zones.


Optional Upgrades & Customization

Marine Upgrade

  • Corrosion protection coating on fins, coils, and outdoor casing
  • AISI 316 stainless steel fasteners
  • Salt spray tested to ASTM B117-18
  • Critical for offshore platforms and coastal installations

Refrigerant Options

  • Standard: R32 refrigerant
  • Optional: R410a retrofit with complete re-labeling and re-charging

Power Configurations

  • Standard: 50Hz
  • Optional: 50Hz/60Hz upgrade with re-labeling
  • ATEX zone 2 or 22 converter for 3-phase systems (400-440V or 400-460V)

Protection & Accessories

  • ATEX isolating switch
  • Power split box
  • Offshore corrosion resistance treatment
  • Enhanced weatherproofing for extreme climates

Spare Parts Available:

  • Outdoor PCBs
  • Fan motors
  • Compressors
  • Condensing coils

Installation Considerations

Piping Requirements

  • Maximum piping length varies by model: 20-85 meters
  • Maximum level difference: 15-30 meters (outdoor unit to indoor unit)
  • Both liquid and gas pipes require heat insulation
  • Liquid pipe diameters: 6.35-10 mm OD
  • Gas pipe diameters: 9.52-15.9 mm OD

Placement Guidelines

  • Ensure adequate ventilation around the unit
  • Protect from direct exposure to corrosive substances
  • Consider noise levels when placing near occupied areas
  • Allow service access on all sides
  • For offshore/marine installations, marine upgrade is essential

Applications & Industries

ATEX outdoor units are essential for complete split system installations in oil & gas facilities, petrochemical plants, chemical processing, pharmaceutical manufacturing, offshore platforms, and food & beverage industries. They can be installed in classified Zone 2 and Zone 22 outdoor areas or in safe zones when paired with ATEX-certified indoor units in hazardous spaces.


ATEX Certification & Safety

Gas Atmospheres (Zone 2):

  • Outdoor Unit: II 3G Ex h nAC IIB (+H2) T3 Gc

Dust Atmospheres (Zone 22):

  • Outdoor Unit: II 3D Ex tc h IIIB (+H2) T150°C Dc

Applied Standards:
EN 60079-0, EN 60079-11, EN 60079-15, EN 60079-31, EN 60079-36, EN 80079-37

Compliant with: EU Directive 2014/34/EU (ATEX 114)

All ATEX modifications and certifications are performed by Ex-Machinery in our dedicated workshop in Ridderkerk, The Netherlands, ensuring the highest quality standards and full regulatory compliance.


Download Technical Datasheets

Write Your Own Review
You're reviewing:Outdoor Units for ATEX Zones | Zone 2 & 22 Explosion-Proof Condensers

Datasheets

>> Datasheet Best Buy Series [PDF]
>> Datasheet High Ambient Series [PDF]
>> Datasheet Power Inverter Series [PDF]
>> Datasheet Classic Series [PDF]