Armadex Ex UniCase - ATEX/IECEx Tablet Enclosure, Zone 2/22

€1,700.00
*Prices are Excl. VAT, duty and shipping costs and may change due to exchange rate.
SKU
B7-S29P-311101102-1

Certified ATEX and IECEx enclosure for Zone 2 and Zone 22 (Ex nR IIC T6 Gc, Ex tc IIIC T85°C Dc, IP64) that takes one supported 10 to 11 inch tablet from Apple, Samsung or Microsoft via device-specific inlays. EUR 1,700 excl. VAT for the enclosure including the inlay set for one supported tablet, tablet not included.

Armadex Ex UniCase ATEX/IECEx Tablet Enclosure for Zone 2/22

Zones: Zone 2 (gas) • Zone 22 (dust) | Certification: ATEX • IECEx | Protection: Ex nR • Ex tc • IP64 | Manufacturer: Armadex

The Armadex Ex UniCase is a certified enclosure that allows a standard 10 to 11 inch tablet from Apple, Samsung or Microsoft to be used in hazardous areas classified as Zone 2 (gas) and Zone 22 (dust). For buyers looking for an ATEX tablet or an explosion proof tablet for Zone 2, the UniCase takes a different route: the explosion protection is provided by the enclosure, not by the tablet itself.

The enclosure is certified under ATEX (OBAC 26 ATEX 0194X) and IECEx (IECEx OBAC 26.0005X) and is marked II 3G Ex nR IIC T6 Gc and II 3D Ex tc IIIC T85°C Dc. It is manufactured by Armadex Explosion Protection B.V. in Ridderkerk, the Netherlands.

Price: EUR 1,700 excl. VAT for the Ex UniCase enclosure including the device-specific inlay set for one supported tablet. The tablet is not included. Complete sets with a tablet are listed in the table below.


How It Works

One Certified Enclosure

The ATEX and IECEx certificates cover the enclosure, which is designed for the integration of low-power electronic devices such as tablets. The same certified enclosure is used for every supported tablet model.

Device-Specific Inlays

For each supported tablet, Armadex supplies four device-specific ABS corner inlays matched to the geometry of that model. They hold the tablet in position inside the enclosure and keep its physical buttons usable.

Replace or Upgrade the Tablet

Because the enclosure is separate from the device, the tablet can be replaced or upgraded without changing the certified enclosure. Moving to another supported model means fitting the matching inlay set. Additional inlay sets are available on request.

Tablet Functions Remain Usable

The touchscreen is operated through the transparent front cover, and three stainless steel push buttons operate the tablet's own buttons via a patented inlay system. The cameras, microphones and speakers remain usable, and wireless data is transmitted via Wi-Fi and Bluetooth.


Supported Tablets and Complete Sets

The enclosure on this page includes the inlay set for one supported tablet of your choice. If you also need the tablet, choose a complete set: Ex UniCase enclosure, inlay set and tablet. The set price shown is for the base configuration; all configurations and prices are listed on each set page.

Tablet Storage options Price complete set from (excl. VAT) Details
Apple iPad (A16), 11 inch 128 GB / 256 GB / 512 GB EUR 2,121 View set
Apple iPad Air 11 inch (M4) 128 GB / 256 GB / 512 GB / 1 TB EUR 2,385 View set
Apple iPad Pro 11 inch (M5) 256 GB / 512 GB / 1 TB / 2 TB EUR 2,790 View set
Samsung Galaxy Tab S11, 11 inch 128 GB / 256 GB / 512 GB EUR 2,526 View set
Samsung Galaxy Tab S10 FE, 10.9 inch 128 GB / 256 GB EUR 2,220 View set
Samsung Galaxy Tab A11+, 11 inch 128 GB / 256 GB EUR 1,972 View set
Microsoft Surface Go 4, 10.5 inch 64 GB / 128 GB / 256 GB EUR 2,589 View set
Enclosure only (bring your own supported tablet) Includes the inlay set for one supported tablet EUR 1,700 This product

Sets with the Apple iPad Air 11 inch (M3) and the Apple iPad Pro 11 inch (M4) are run-out models; contact us for availability. Their successors are the iPad Air 11 inch (M4) and the iPad Pro 11 inch (M5), which use the same certified enclosure. Is your tablet not listed? Contact us and we will check whether a matching inlay version is available.


Certification

ATEX marking II 3G Ex nR IIC T6 Gc
II 3D Ex tc IIIC T85°C Dc
ATEX certificate Type examination certificate OBAC 26 ATEX 0194X, Issue 0, dated 12 May 2026
Directive 2014/34/EU (ATEX)
Standards (ATEX) EN IEC 60079-0:2018, EN IEC 60079-15:2019, EN IEC 60079-31:2024
IECEx marking Ex nR IIC T6 Gc
Ex tc IIIC T85°C Dc
IECEx certificate IECEx OBAC 26.0005X, Issue 0, date of issue 28 May 2026
Standards (IECEx) IEC 60079-0:2017 (Edition 7.0), IEC 60079-15:2017 (Edition 5.0), IEC 60079-31:2022 (Edition 3.0)
Protection concepts Ex nR, restricted breathing (gas)
Ex tc, protection by enclosure (dust)
Zones Zone 2 (gas) and Zone 22 (dust)
Certified equipment Armadex Ex UniCase
Certification body OBAC Sp. z o.o., Gliwice, Poland
Manufacturer Armadex Explosion Protection B.V., Ridderkerk, the Netherlands

Understanding the Protection and the Marking

Ex nR (restricted breathing): a type of protection "n" to IEC 60079-15 for Zone 2. The sealed enclosure limits the entry of gas, so that during the short periods in which an explosive gas atmosphere may be present outside, the concentration inside the enclosure stays below the lower explosive limit.

Ex tc (protection by enclosure): dust protection to IEC 60079-31 for Zone 22, based on keeping dust out of the enclosure and limiting the maximum surface temperature.

Not intrinsically safe, not flameproof: the UniCase does not use intrinsic safety (Ex i) or a flameproof enclosure (Ex d). It is certified for Zone 2 and Zone 22 only, not for Zone 1 or Zone 21.

II 3G / II 3D: equipment group II, category 3, for gas (G) and dust (D) atmospheres.

IIC T6 Gc: gas group IIC (also covers IIA and IIB), temperature class T6 (maximum surface temperature 85°C), equipment protection level Gc.

IIIC T85°C Dc: dust group IIIC (also covers IIIA and IIIB), maximum surface temperature 85°C, equipment protection level Dc.


Specific Conditions of Use (X)

Both certificate numbers carry the suffix "X". The following specific conditions of use apply:

  • The Ex UniCase may only be opened or closed outside the hazardous area.
  • The USB lid and the test port plug must always be fitted in the hazardous area.
  • The device must be protected from impacts with high impact energy, against excessive UV light and against processes that generate high electrostatic charges.

In addition, the attachment to the IECEx certificate states that a routine test according to IEC 60079-15, clause 10.3, is required for each new type of mobile device installed in the nR enclosure that has not been tested before.


Enclosure Construction and Specifications

Compatible tablets 10 to 11 inch tablets from Apple, Samsung and Microsoft (see supported tablets above)
Main housing Milled frame of ESD-safe POM-C
Display window Transparent polycarbonate front cover, touchscreen operation through the window
Back plate Transparent plexiglass (acrylic) back plate
Seal 3 mm silicone rubber O-ring between back plate and housing
Inlays Four device-specific, modular ABS corner inlays for positioning the tablet
Push buttons 3 stainless steel push buttons, operating the tablet's internal buttons via a patented inlay system
User interface Touchscreen and 3 mechanical push buttons
External port USB-C in the side of the frame, for use outside the hazardous area only; test port with plug
Wireless communication Wi-Fi, Bluetooth
Power supply (rated) Internal Li-ion battery, 3.7 to 7.6 V DC
Degree of protection IP64 (dust-tight, protected against splashing water)
Ambient temperature, operating -20°C to +50°C
Ambient temperature, storage -20°C to +60°C

Applications

The Ex UniCase is intended for professional use in hazardous areas classified as Zone 2 (gas) or Zone 22 (dust), where a standard tablet is needed behind a certified enclosure.

Inspection

Inspection rounds and checks in Zone 2 and Zone 22 areas, using the apps on the installed tablet.

Documentation

Recording observations and findings on site, using the touchscreen and the tablet's cameras.

Reporting

Completing reports in the field and sending data via Wi-Fi or Bluetooth.

Field Operation

Operating applications on site in classified areas, with the touchscreen and push buttons.

Before use, check that the zone classification, gas group, dust group and temperature class of the location are covered by the marking, and observe the specific conditions of use listed above.


What's Included

  • Armadex Ex UniCase enclosure
  • Device-specific inlay set for one supported tablet of your choice

The tablet is not included. For an enclosure with tablet, choose one of the complete sets above.


Documentation

Write Your Own Review
You're reviewing:Armadex Ex UniCase - ATEX/IECEx Tablet Enclosure, Zone 2/22

Datasheets